Randox Compact Chemistry Analyzer
Automation Fully Automatic Brand Randox Model Name/Number Rx monaco Features Precision,Reliability & Accuracy Usage/Application Hospital Wash Station 12 stage washing system including acid,alkali,pure water wash steps cleans the 120 reusable cuvete Reaction Carousel The RX monaco has a cycle time of 15 seconds. Features
- Up to 300 photometric tests/hr or up to 480 tests/hour with optional ISE module
- Continuous sample loading – easy accessibility to the sample sectors without the need to open the analyzer
- Intelligent operating software with automatic reflexing testing, QC scheduling and automatic method calibration.
- 72 Positions reagent tray with onboard cooling and Internal Barcode scanner
- 95 positions sample tray with internal barcode scanner.
- Clot detection and probe collision prevention system for safe and reliable operation.
Technical Specifications
THROUGHPUT
Up to 300 photometric tests/hr or up to 480 tests/hour with optional ISE module
SAMPLES AND REAGENT
Samples
- Sample volume: 2 to 100 μl/test (in increments of 1 μl).
- Sample tray: 95 (5 racks x 19 positions).
- Primary tube (length up to 100 mm)
- Pediatric vial
Reagents
- Reagent tray: up to 72 single reagents
- Multiple vials per test
- Refrigerated compartment at 8 °C ± 1 °C
SAMPLES AND REAGENT HANDLING
- Pipetting Arm:One pipetting arm for sample and reagent, including reaction preheater, probe collision sensor, capacitive level sensor and reaction mixer.
- Probe cleaning : Internal and external
REACTION
- Water consumption : 1.5 l / hour (deionized)
- Reaction cuvette: 80 re-usable plastic cuvettes.Optical length: 6 mm
- Reaction volume: 180-500 μl
- Warm air incubator: 37 °C
- Reaction time : 0 to 10 min.
- Washing station: 6 stages
ANALYTICAL MODES
- Full random access or batch mode operation with STAT sample priority function
- Multiple methodology options- End point, Kinetic, Coagulation, Calculated, Turbidimetry, enzymes and Drugs of Abuse.
- Choice of calibration options- Linear, Multilinear, Sigmoid, Logit-log ( 4 & 5 point) & spline
- Automatic sample dilution and reflex testing
List number: - R
unless otherwise indicated the content of this “website” is the proprietary property of its owners. however, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appear with the listed products, it is only used for the purpose of identification of those products. we do not claim as association with the mark owners, unless otherwise so specified.